| Exemption: |
• You are exempt from the requirement not to install the shut off valve between the safety relief valve and the
container or systems in the following situations: |
|
– A three-way valve installed under two safety relief valves, each with |
|
▪ The required rate of discharge; |
|
AND |
|
▪ Installed to allow either of the safety relief valves to be closed off but not at the same time. |
|
– Two separate relief valves are installed with individual shut off valves. |
|
▪ The two shut off valve stems must be mechanically interconnected to allow the full required flow of one
safety relief valve at all times. |
|
– When a safety relief valve manifold that allows: |
|
▪ One valve of two or more to be closed off; |
|
AND |
|
▪ The remaining valve or valves will provide not less than the rate of discharge shown on the manifold
nameplate. |
• Follow additional requirements found in Table 13,
Appurtenances for Systems Mounted on Farm Equipment for
Ammonia Application| If you have: |
Then make sure they: |
| Filling
connections |
Are fitted with one of the following: |
|
– |
A combination back-pressure
check valve and excess flow
valve |
|
– |
One double or two single
back-pressure check valves |
|
– |
A positive shut off valve used
with either an: |
|
▪ |
Internal back-pressure check
valve; |
|
|
OR |
|
▪ |
Internal excess flow valve |
|
Exemption: |
|
• |
An excess-flow valve is not
required in either of the
following: |
|
– |
Vapor connection providing
you meet both of the
following: |
|
▪ |
The controlling orifice is not in
excess of seven-sixteenths of
an inch in diameter; |
|
|
AND |
|
▪ |
The valve is hand-operated
(attached hand-wheel or
equivalent) shut off valve; |
|
|
OR |
|
– |
In the liquid withdrawal line if
the controlling opening
between the contents of the
container and the outlet of the
shut off valve do not exceed
7/16 inch in diameter. |
| |
Note: To assist in filling applicator
tanks, you are allowed to bleed
vapors into the open air if you meet
the above requirements. |
| Columnar-type
gauges |
Are shielded against the direct rays
of the sun |
|
Are equipped with all of the
following: |
|
– |
Shut off valves having metallic
hand-wheels |
|
– |
Excess flow valves |
| |
– |
Extra heavy glass that is
adequately protected with a
metal housing applied by the
gauge manufacturer |
| An applicator
tank that is both
of the following: |
Use an automatic break-away type,
self-closing, coupling |
| Trailed; |
|
|
| AND |
|
|
| The metering
device is
remotely
mounted (for
example on a
tractor tool bar) |
|
|
| Hydrostatic relief
valves |
Are installed between each pair of
valves in the liquid ammonia piping
or hose. |