WAC 296-826-30025   Systems mounted on trucks, semi-trailers, and trailers.  

     You must:

     • Construct and test containers, when transported within the state of Washington, according to both of the following:

     – A minimum design pressure of 250 psig

     – The Unfired Pressure Vessel Code.

     • Construct containers used for interstate transport according to DOT regulations.

     • Make sure the shell or head thickness of any container is at least 3/16 of an inch.

     • Make sure electrical lighting circuits meet all of the following:

     – Have suitable over-current protection, such as fuses or automatic circuit breakers.

     – Are suitably secured, insulated, and protected against physical damage.

     – Have wiring with sufficient carrying capacity and mechanical strength.

     • Use only electric light.



[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 06-10-067, § 296-826-30025, filed 5/2/06, effective 9/1/06.]