WAC 296-818-40015   Inspection and maintenance.  

     You must:

     • Make sure the exhaust ventilation system is fully operational by checking the static pressure drop at the exhaust ducts leading from the equipment at both of the following times:

     – When installation is completed

     – Annually after installation.

     • Repair or clean exhaust systems when either of the following occur:

     – Dust leaks are found; or

     – The pressure drop gauge indicates a change exceeding 20 percent.

     • Use an abrasive separator to separate larger particles for reuse on installations where abrasive is recirculated.

     • Set up dust collecting equipment to do both of the following:

     – Empty and remove accumulated dust without contaminating work areas

     – Discharge the air used in blast cleaning equipment.

Note: Dispose fine dust from dry collectors by doing one of the following:
• Emptying and transporting the fine dust in enclosed containers
• Using a sluice with a wetting process to contain the dust.




[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 06-12-074, § 296-818-40015, filed 6/6/06, effective 9/1/06.]