WAC 296-809-60004
Follow these alternate entry
procedures for permit-required confined spaces.
You must:
• Use the following alternate entry procedures:
– Eliminate any unsafe conditions before removing an
entrance cover.
▪ When entrance covers are removed, promptly guard the
opening with a railing, temporary cover, or other temporary
barrier to prevent accidental falls through the opening and
protect entrants from objects falling into the space.
▪ Certify that preentry measures have been taken (such as
safe removal of the cover and having protection needed to
gather preentry data), with the date, location of the space,
and signature of the person certifying.
▪ Make the preentry certification available before entry
to each entrant.
– Before an employee enters the confined space, test the
internal atmosphere with a calibrated, direct-reading
instrument for all of the following, in this order:
▪ Oxygen content.
▪ Flammable gases and vapors.
▪ Potential toxic air contaminants.
– Provide entrants, or their authorized representatives,
with an opportunity to observe the preentry and periodic
testing.
– Make sure the atmosphere within the space is not
hazardous when entrants are present.
– Use continuous forced air ventilation, as follows:
▪ Wait until the forced air ventilation has removed any
hazardous atmosphere before allowing entrants into the space.
▪ Direct forced air ventilation toward the immediate
areas where employees are, or will be, and continue
ventilation until all employees have left the space.
▪ Provide the air supply from a clean source and make
sure it does not increase hazards in the space.
– Test the atmosphere within the space as needed to make
sure hazards do not accumulate.
– If a hazardous atmosphere is detected during entry, do
all of the following:
▪ Evacuate employees from the space immediately.
▪ Evaluate the space to determine how the hazardous
atmosphere developed.
▪ Implement measures to protect employees from the
hazardous atmosphere before continuing the entry operation.
▪ Verify the space is safe for entry before continuing
the entry operation.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050,
and 49.17.060. 04-03-081, § 296-809-60004, filed 1/20/04,
effective 5/1/04.]