WAC 296-806-47508
Follow these requirements for feed
roll guarding.
You must:
• Make sure that feed rolls have a hood or guard to
prevent the operator's hands from coming in contact with the
in-running rolls at any point.
• Make sure that the guard meets ALL of the following:
– Is constructed of heavy material, preferably metal.
– The bottom of the guard comes down to within
three-eighths inch of the plane formed by the bottom or
working surfaces of the feed rolls.
▪ When the three-eighths inch distance is increased to
three-quarter inch, the lead edge of the hood must be extended
to five and one-half inches or more in front of the nip point
between the front roll and the work.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050,
and 49.17.060. 04-14-028, § 296-806-47508, filed 6/29/04,
effective 1/1/05.]