WAC 296-806-42022
Provide pedestrian overpasses for conveyors.
You must:
• Provide a pedestrian overpass covering the full width of a passageway if
one
of these conditions exists:
– The working strand of a conveyor crosses within three feet of floor level.
– Workers must step over the strand and trough at or below floor level.
• Provide a pedestrian overpass where workers cannot pass under the conveyor safely.
– The sides of the crossing platform must have standard railings if
one
of the following exists:
▪ The overpass is more than four feet high.
▪ The conveyor feeds a dangerous machine such as saws, chippers, hogs, or galvanizing tanks.
Reference:
For guardrail requirements see, Railing, toeboards, and cover specifications, WAC
296-24-75011
.
[Statutory Authority: RCW
49.17.010
,
49.17.040
,
49.17.050
, and
49.17.060
. 04-14-028, § 296-806-42022, filed 6/29/04, effective 1/1/05.]