WAC 296-806-41506
Follow these requirements for
compactor access doors and covers.
You must:
• Make sure access covers meet at least one of the
following:
– Interlocked.
– Secured by a lockable device.
– Removable by hand tools only.
• Make sure any loading chamber access door has an
interlock system that prevents cycling motion when the door is
open.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050,
and 49.17.060. 04-14-028, § 296-806-41506, filed 6/29/04,
effective 1/1/05.]