WAC 296-806-41504
Follow these requirements for
compactor controls.
You must:
• Follow these requirements for compactor controls:
– Each control must have its function clearly labeled.
– Controls must be designed and located to prevent them
from unintentionally activating.
– Electric stop buttons, including emergency stop
buttons, must be:
▪ Red in color, distinguishable from all other controls
by size, and not recessed.
– Emergency stop controls must be either:
▪ Readily accessible to the operator;
OR
▪ Located within three feet (91.4 cm) of the point of
operation or feed area or if chute fed, within three feet
(91.4 cm) of the access door.
– An electrical disconnect must be located within sight,
no more than fifty feet (1,524 cm), from the operating control
panel.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050,
and 49.17.060. 04-14-028, § 296-806-41504, filed 6/29/04,
effective 1/1/05.]