WAC 296-307-20515
What requirements apply to pneumatic
powered tools and hose? (1) The operating trigger on portable
pneumatic powered tools must be located to minimize the
possibility of accidental operation and arranged to close the air
inlet valve automatically when the operator removes pressure.
(2) A tool retainer must be installed on each tool that
would otherwise be ejected from the hose.
(3) Hose and hose connections used for conducting compressed
air to utilization equipment must be designed for the pressure
and service to which they are subjected.
[97-09-013, recodified as § 296-307-20515, filed 4/7/97,
effective 4/7/97. Statutory Authority: RCW 49.17.040,[49.17.]050
and [49.17.]060. 96-22-048, § 296-306A-20515, filed
10/31/96, effective 12/1/96.]