WAC 296-305-06517
Drill tower training facilities. (1)
Permanent fixed ladders on the outside of drill towers and
drill buildings are exempt from the requirements of offset
platform landings and ladder cage guards.
(2) Drill tower construction and operations shall comply
with the following:
(a) Burn buildings used for live fire training shall be
engineered for such use.
(b) Drill towers shall not be used for live fire training
except when burn rooms are provided.
(c) Burn rooms, if included in the building, shall be
engineered into drill towers.
(d) All walking surfaces in the drill tower shall be slip
resistant.
(e) Railings shall be designed with a four-to-one safety
ratio for 250 pound firefighters who may be operating a
charged hose line on the fire escape.
(f) Rappelling anchors shall be engineered to support
4500 pounds per person supported by the anchor.
(g) Rappelling anchors shall be readily identifiable.
(h) Rappelling anchors shall be certified by a structural
engineer.
[Statutory Authority: RCW 49.17.010, [49.17].050 and[49.17].060
. 96-11-067, § 296-305-06517, filed 5/10/96,
effective 1/1/97. Statutory Authority: RCW 49.17.040 and 49.17.050. 83-24-013 (Order 83-34), § 296-305-06517, filed
11/30/83; Order 77-20, § 296-305-06517, filed 10/18/77 and
Emergency Order 77-24, filed 11/17/77, effective 12/17/77.]