WAC 296-150P-0330
What is required for comprehensive
design-plan approval? If you are the manufacturer applying for
state-plan approval:
(1) You must submit two sets of comprehensive design plans
(do not send originals) to us for approval. Design plans must be
accompanied by the initial filing fee, if appropriate, and the
design-plan fee. (See WAC 296-150P-3000.)
(2) Your comprehensive design plan must indicate compliance
with the appropriate ANSI standards in the following plans and
drawings:
(a) Floor plans relating to fire and life safety,
electrical, plumbing, liquefied petroleum (LP) and/or natural gas
systems and appliances, and air conditioning systems, if
applicable, of each recreational park trailer.
(b) Plumbing line drawings which describe the size, length
and location of gas piping lines, liquid and body waste lines,
liquid and body waste tanks, and potable water tanks.
(c) Electrical drawings.
(d) Structural drawings showing compliance with ANSI A119.5,
Chapter 5.
Note:
We will provide a check list with detailed requirements for each type of plan upon request.
(3) Current comprehensive design plans must be available at
each manufacturing location.