WAC 296-150C-0970
Roof construction. (1) All roofs must be
framed and tied into the framework and supporting walls to form
an integral part of the commercial coach.
(2) All trusses must be laterally braced.
(3) All roof decks must be designed and built with
sufficient slope or camber to assure adequate drainage, or must
be designed to support maximum loads including possible ponding
of water due to deflection.
(4) Cutting roof framework members for passage of
electrical, plumbing, or mechanical systems is prohibited except
where substantiated by engineering analysis.
(5) Electrical, plumbing, or mechanical systems must not
penetrate the roofing membrane unless the penetration point is
adequately sealed.
(6) Ventilation. Enclosed attics and enclosed rafter spaces
formed where ceilings are applied directly to the underside of
roof rafters shall have cross ventilation for each separate space
by ventilating openings protected against the entrance of rain
and snow. Where eave or cornice vents are installed, insulation
shall not block the free flow of air. A minimum of 1 inch of air
space shall be provided between the insulation and roof
sheathing. The net free ventilating area shall not be less than
1/150 of the space ventilated, except:
(a) The area may be 1/300, provided 50 percent of the
required opening area is provided by ventilators located in the
upper portion of the space to be ventilated at least 3 feet above
eave or cornice vents; or
(b) A vapor barrier not exceeding 1 perm is installed on the
warm side of the attic insulation.
[Statutory Authority: RCW 43.22.340, 43.22.350, 43.22.355,
43.22.360, 43.22.400, 43.22.432, 43.22.433, 43.22.434, 43.22.450,
43.22.480, and 43.22.485. 00-17-148, § 296-150C-0970, filed
8/22/00, effective 9/30/00. Statutory Authority: RCW 43.22.340,[43.22.]355
, [43.22.]360, [43.22.]432, [43.22.]440 and[43.22.]480
. 96-21-146, § 296-150C-0970, filed 10/23/96,
effective 11/25/96.]