WAC 296-96-05070
What car enclosure requirements apply
to lifts? Lift cars must have their sides enclosed with solid
panels or openwork that will reject a 2-inch diameter ball. On the car sides where there is no gate (door), the enclosure
must extend to a height of at least 48 inches from the floor
or to a height necessary to enclose the materials that are
being moved. On the car side next to the counterweight
runway, the enclosure must extend vertically to the car top or
underside of the car crosshead and horizontally to at least 6
inches on each side of the runway. Material lifts in
unenclosed hoistways must have a car gate that is constructed
of the same material as the car enclosure. The gate must be
the same height as the sidewalls of the car enclosure and must
be provided with a latching device.
[Statutory Authority: RCW 70.87.020, 70.87.030, 70.87.034,
70.87.120, 70.87.185, 70.87.190, 2002 c 98, 2003 c 143 and
2004 c 66. 04-12-047, § 296-96-05070, filed 5/28/04,
effective 6/30/04. Statutory Authority: RCW 70.87.020,
70.87.030, 70.87.034, 70.87.120, 70.87.185 and chapter 70.87 RCW. 01-02-026, § 296-96-05070, filed 12/22/00, effective
1/22/01.]