WAC 296-79-29035
Piling and unpiling pulp. (1) Piles of wet lap pulp (unless palletized)
must be stepped back one-half the width of the sheet for each 8
feet of pile height. Sheets of pulp must be interlapped to make
the pile secure. Pulp must not be piled over pipelines to
jeopardize pipes, or so as to cause overloading of floors, or to
within 18 inches below sprinkler heads.
(2) Piles of pulp must not be undermined when being unpiled.
(3) Floor capacities must be clearly marked on all floors.
(4) When sprinklers are used for fire protection in the
storage area, baled paper and rags must be stored in stable piles
which do not extend into the area necessary for the proper
function of sprinkler systems.
[Statutory Authority: RCW 49.17.010, [49.17].040 and[49.17].050
. 99-16-083, § 296-79-29035, filed 8/3/99, effective
11/3/99; Order 76-7, § 296-79-29035, filed 3/1/76; Order 74-24, §
296-79-29035, filed 5/6/74.]