WAC 296-79-230
Confined spaces. (1) Entry into confined spaces must be in accordance with
chapter 296-62 WAC, Part M.
(2) All equipment necessary to perform the work, including
safety equipment, must be at the confined space and must be
inspected or tested to assure that it functions properly.
(3) Protective equipment that will afford proper protection
to the employee from any condition which may arise based on the
hazard assessment, must be available either at the entrance or
within the confined space.
(4) Electrical circuits leading into confined spaces where
electrical conductive hazards exist must be protected by a ground
fault interrupter or the voltage must not exceed 24 volts.
(5) Battery operated flashlights or lantern must be readily
available for use by persons working in areas where escape would
be difficult if normal lighting system should fail. Only
explosion-proof type lights may be taken into any atmosphere
which may contain an explosive concentration.