WAC 296-78-71001
General. (1) Construction when not
specifically covered in these standards shall be governed by
such other standards adopted by the department of labor and
industries as may apply.
(2) All buildings, docks, tramways, walkways, log dumps
and other structures shall be so designed, constructed, and
maintained as to provide a safety factor of four. This means
that all members shall be capable of supporting four times the
maximum load to be imposed. This provision refers to
buildings, docks and so forth designed and constructed
subsequent to the effective date of these standards and also
refers in all cases where either complete or major changes or
repairs are made to such buildings, docks, tramways, walkways,
log dumps and other structures.
(3) Basements on ground floors under mills shall be
evenly surfaced, free from unnecessary obstructions and
debris, and provided with lighting facilities in compliance
with the requirements of the safety and health core rules, WAC 296-800-210.
(4) All engines, motors, transmission machinery or
operating equipment installed in mill basements or ground
floors shall be equipped with standard safeguards for the
protection of workers.
(5) Flooring of buildings, ramps and walkways not subject
to supporting motive equipment shall be of not less than
two-inch wood planking or material of equivalent structural
strength.
(6) Flooring of buildings, ramps, docks, trestles and
other structure required to support motive equipment shall be
of not less than full two and one-half inch wood planing or
material of equivalent structural strength. However, where
flooring is covered by steel floor plates, two inch wood
planking or material or equivalent structural strength may be
used.
(7) Walkways, docks, and platforms.
(a) Walkways, docks and platforms shall be constructed
and maintained in accordance with the requirements of WAC 296-24-735 through 296-24-75011 and WAC 296-800-270.
(b) Maintenance. Walkways shall be evenly floored and
kept in good repair.
(c) Where elevated platforms are used they shall be
equipped with stairways or ladders in accordance with WAC 296-24-765 through 296-24-81013, WAC 296-800-250 and chapter 296-876 WAC, Ladders, portable and fixed.
[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050,
49.17.060. 06-16-020, § 296-78-71001, filed 7/24/06,
effective 12/1/06; 04-18-080, § 296-78-71001, filed 8/31/04,
effective 11/1/04; 03-06-076, § 296-78-71001, filed 3/4/03,
effective 8/1/03. Statutory Authority: RCW 49.17.010,[49.17].040
, and [49.17].050. 01-11-038, § 296-78-71001,
filed 5/9/01, effective 9/1/01. Statutory Authority: RCW 49.17.040, 49.17.050 and 49.17.240. 81-18-029 (Order 81-21),