WAC 296-62-07304
Definitions. The definitions set forth in
this section apply throughout WAC 296-62-073 through296-62-07316
.
(1) Absolute filter - is one capable of retaining 99.97
percent of a mono disperse aerosol of 0.3 micron size particles.
(2) Authorized employee - an employee whose duties require
him to be in the regulated area and who has been specifically
assigned to those duties by the employer.
(3) Clean change room - a room where employees put on clean
clothing and/or protective equipment in an environment free of
carcinogens listed in WAC 296-62-07302. The clean change room
shall be contiguous to and have an entry from a shower room, when
the shower room facilities are otherwise required in this
section.
(4) Closed system - an operation involving carcinogens
listed in WAC 296-62-07302 where containment prevents the release
of carcinogens.
(5) Decontamination - the inactivation of a carcinogen
listed in WAC 296-62-07302 or its safe disposal.
(6) Disposal - the safe removal of a carcinogen listed in
WAC 296-62-07302 from the work environment.
(7) Emergency - an unforeseen circumstance or set of
circumstances resulting in the release of a carcinogen which may
result in exposure to or contact with any carcinogen listed in
WAC 296-62-07302.
(8) External environment - any environment external to
regulated and nonregulated areas.
(9) Isolated system - a fully enclosed structure other than
the vessel of containment of a listed carcinogen which is
impervious to the passage of listed carcinogens and which would
prevent the entry of carcinogens into regulated areas,
nonregulated areas, or the external environment, should leakage
or spillage from the vessel of containment occur.
(10) Laboratory-type hood - a device enclosed on three sides
and the top and bottom, designed and maintained so as to draw air
inward at an average linear face velocity of 150 feet per minute
with a minimum of 125 feet per minute, designed, constructed and
maintained such that an operation involving a listed carcinogen
within the hood does not require the insertion of any portion of
any employees' body other than his hands and arms.
(11) Nonregulated area - any area under the control of the
employer where entry and exit is neither restricted nor
controlled.
(12) Open-vessel system - an operation involving listed
carcinogens in an open vessel, which is not in an isolated
system, a laboratory-type hood, nor in any other system affording
equivalent protection against the entry of carcinogens into
regulated areas, nonregulated areas, or the external environment.
(13) Protective clothing - clothing designed to protect an
employee against contact with or exposure to listed carcinogens.
(14) Regulated area - an area where entry and exit is
restricted and controlled.
[Statutory Authority: RCW 49.17.010, [49.17].040, [49.17].050. 02-12-098, § 296-62-07304, filed 6/5/02, effective 8/1/02. Statutory Authority: Chapter 49.17 RCW. 87-24-051 (Order
87-24), § 296-62-07304, filed 11/30/87. Statutory Authority:
RCW 49.17.040 and 49.17.050. 81-07-048 (Order 81-4), §
296-62-07304, filed 3/17/81. Statutory Authority: RCW 49.17.040, 49.17.050, 49.17.240, chapters 42.30 and 43.22 RCW. 80-17-014 (Order 80-20), § 296-62-07304, filed 11/13/80.]