WAC 296-56-60055
Carbon monoxide. (1) Exposure limits. The carbon monoxide content of the atmosphere in a room, building, vehicle, railcar or any enclosed space shall be maintained below fifty parts per million (0.005%) as an eight-hour time-weighted average. Employees shall be removed from the enclosed space if the carbon monoxide concentration exceeds one hundred parts per million (0.01%).
(2) Testing. Tests to determine carbon monoxide concentration shall be made whenever necessary to ensure that employee exposure does not exceed the limits specified in subsection (1) of this section.
(3) Instrumentation. Tests for carbon monoxide concentration shall be made by designated persons using gas detector tube units certified by NIOSH under 30 CFR Part 11 or other measuring instruments whose accuracy is as great or greater.
(4) Records. A record of the date, time, location and result of carbon monoxide tests shall be available for at least thirty days.
[Statutory Authority: RCW 49.17.040 and 49.17.050. 86-03-064 (Order 86-02), § 296-56-60055, filed 1/17/86; 85-01-022 (Order 84-24), § 296-56-60055, filed 12/11/84.]