WAC 296-52-60095
Fire. (1) Magazines/buildings. Flame or
flame producing devices must not be ignited within fifty feet of
any magazine or explosives manufacturing building.
(2) Explosives handling.
(a) All sources of fire or flame, including smoking and
matches, are prohibited within one hundred feet of the blast site
while explosives are being handled or used.
(b) Explosives must not be handled near:
(i) Open flames
(ii) Uncontrolled sparks
OR
(iii) Energized electric circuits
(3) Fire incident precautions. In the event of a fire:
(a) All employees must be removed to a safe area
(b) The fire area must be guarded against intruders
(c) The fire must not be fought where there is danger of
contact with explosives.
[Statutory Authority: RCW 49.17.010, [49.17].040, and[49.17].050
. 02-03-125, § 296-52-60095, filed 1/23/02, effective
3/1/02.]