WAC 296-17A-0306
Classification 0306.
0306-00 Plumbing, N.O.C
Applies to contractors engaged in plumbing work not
covered by another classification (N.O.C.). Work contemplated
by this classification includes activities such as, but not
limited to, rough-in plumbing work as part of new or remodel
projects, placement of pipe (plastic, copper or galvanized),
cutting and/or threading pipe, soldering, welding or gluing
all types of pipe, fittings or valves, installation of
fixtures (sinks, showers and tubs, faucets), installation of
appliances (dishwashers, hot water tanks, refrigerators with
ice and water dispensers), and other necessary plumbing
activities in connection with water supplies, water carrying,
dispensing, or drainage systems. This classification includes
incidental side sewer hook ups (street to house) when
performed by a plumbing contractor subject to this
classification, and only when it is performed as a part of a
plumbing contract which includes installation of waste lines
and waste carry systems within a building; and sewer pipe
cleaning including services provided by service providers
engaged in cleaning or unplugging waste lines.
This classification excludes side sewer hook ups
performed as part of an excavation contract which are to be
reported separately in classification 0101, and underground
water line or water main construction which is to be reported
separately in classification 0107.
Special note: This classification includes the
installation of display areas or showrooms which provide
prospective customers an opportunity to inspect the quality of
workmanship and products carried by the contractor.
Generally, displays or showrooms are installed where the
contractor stores his materials. It is common for contractors
subject to this classification to sell plumbing fixtures and
supplies, but the intent of these areas is not to sell
products to walk-in customers. Sale of these products by a
plumbing contractor is included in classification 0306.
Classifications 2009, 6309, or similar store classifications
are not to be assigned to a contractor's business. Employees
engaged exclusively in showing the display areas or showrooms
to customers are to be assigned classification 6303 provided
the conditions of the standard exception general reporting
rule have been met.
0306-02 Automatic sprinkler systems or fire extinguishing
systems: Installation, service or repair within buildings
Applies to contractors engaged in the installation,
service or repair of automatic sprinkler or fire extinguishing
systems within buildings. Work contemplated by this
classification includes installation of pipe, fittings,
couplings, valves, hangers, regulators, and alarms in
ceilings, walls and floors, and cutting and/or threading pipe.
These systems are usually equipped to release dry chemicals or
water automatically when the surrounding temperature exceeds a
predetermined limit.
This classification excludes contractors engaged in the
installation, service or repair of outside lawn type and
agricultural/irrigation sprinkler systems who are to be
reported separately in classification 0301, and contractors
engaged in all types of general plumbing installation or
repair work who are to be reported separately in
classification 0306-00.
0306-03 Boilers, steam pipes, water pipes, heating ducts:
Installation of covering insulation
Applies to contractors engaged in the installation of
insulated covering on boilers, steam pipes, water pipes and
heating ducts to help them retain heat. A boiler is a type of
enclosed storage tank erected within a building which heats
and circulates extremely hot water or converts hot water into
steam. Contractors subject to this classification may also
install water jets inside the tanks.
This classification excludes contractors primarily
engaged in the erection of boiler tanks who are to be reported
separately in classification 0306-04, and the removal of
asbestos from boilers which is to be reported separately in
classification 0512.
0306-04 Boilers, N.O.C.: Installation, service or repair
Applies to contractors engaged in the installation,
service or repair of boilers not covered by another
classification (N.O.C.), including boiler scaling and tank
erection within buildings. A boiler is a type of enclosed
storage tank erected within a building which heats and
circulates extremely hot water or converts hot water into
steam. Work contemplated by this classification includes the
erection and/or installation of the boiler or tank (which is
above ground), pipes, tubing, ducts, heating units, valves,
headers, jets and insulation coverings. Also included is the
process of boiler scaling which is the removal of scales or
residue from the tank or pipes using chemicals, steam or
mechanical methods.
This classification excludes contractors primarily
engaged in covering a boiler and pipes with insulation
covering who are to be reported separately in classification
0306-03, and the erection of exterior tanks which is to be
reported separately in classification 0508.
0306-05 Pump installation, service or repair, N.O.C.
Applies to contractors engaged in the installation,
service or repair of pumps related to water or waste carrying
systems, and which are not covered by another classification
(N.O.C.). Work contemplated by this classification applies to
all types of water or sump pumps in connection with
residential or commercial settings, water wells, and
irrigation and drainage systems. A pump is a device that
siphons or transfers material from one source or container to
another. Activities include pump installation or repair
services related to a building's water lines and water
carrying systems, plumbing fixtures, dispensers, swimming
pools and hot tubs, water wells, and agricultural or
irrigation systems.
This classification excludes the installation of water
pumps in connection with drilling operations which is to be
reported separately in classification 0103; the installation
or repair of service station pumps which is to be reported
separately in classification 0603; and contractors engaged in
all types of general plumbing installation or repair work who
are to be reported separately in classification 0306-00.
0306-06 Water softening or treatment systems - installation of
new equipment systems
Applies to establishments engaged in the installation of
plumbing lines for new water conditioning, purifying or
softening systems. Establishments providing this type of
service are not required to be a "licensed plumber" to do the
installation; however, it does involve plumbing work. The
installation involves cutting the water line between the water
source and the building or home. The line is cut with a
hacksaw, reciprocating saw, or copper tube cutter, depending
on the type of pipe involved. After the line is cut, the
water source is connected to the intake of the system and the
building or home is connected to the outlet of the system with
supply and return lines. The bypass unit will allow the water
to remain hard for the outside faucet. A small rubber hose is
installed under the house into the drain. Occasionally, a
sump pump is needed. For plastic pipes, glue is used to seal
the connections. On copper pipes, soldering equipment is used
to secure the connections. Water softening is a process by
which the water passes through a resin tank where calcium ions
are exchanged for sodium ions, resulting in "soft" water.
Periodically, the resin is recharged by "back flushing" with a
saturated salt solution from another tank. Installations of
this type include the two tanks, pressure regulators, valves,
and in new facilities an automatic timer.
Special note: This classification allows for the service
or repair of water softening or treatment systems to be
reported separately in classification 0607 provided accurate
time records are maintained which distinguishes new
installation contract work from service or repair contract
work.
0306-07 Hot water heater: Installation, service or repair
Applies to contractors engaged exclusively in the
installation, service or repair of hot water heater units.
Work contemplated by this classification includes removal of
old units and the installation of new or replacement units.
This includes activities such as disconnecting hot heater
units, removal of plastic, copper or galvanized water pipes,
installing or setting up new or replacement units, installing
new pipes, cutting and/or threading pipe, soldering, welding
or gluing all types of pipe, fittings or valves, filling and
testing the new or replacement units, and wrapping hot water
heaters with insulation blankets.
This classification excludes contractors engaged in all
types of general plumbing work, or when the installation,
service or repair of a hot water heater unit is performed as
part of a general plumbing contract which is to be reported
separately in classification 0306-00.
[07-01-014, recodified as § 296-17A-0306, filed 12/8/06,
effective 12/8/06. Statutory Authority: RCW 51.16.035. 98-18-042, § 296-17-512, filed 8/28/98, effective 10/1/98;
96-12-039, § 296-17-512, filed 5/31/96, effective 7/1/96. Statutory Authority: RCW 51.04.020(1) and 51.16.035. 93-12-093, § 296-17-512, filed 5/31/93, effective 7/1/93;
91-12-014, § 296-17-512, filed 5/31/91, effective 7/1/91. Statutory Authority: RCW 51.16.035. 85-24-032 (Order 85-33),
§ 296-17-512, filed 11/27/85, effective 1/1/86; 85-06-026
(Order 85-7), § 296-17-512, filed 2/28/85, effective 4/1/85;
83-24-017 (Order 83-36), § 296-17-512, filed 11/30/83,
effective 1/1/84; 82-24-047 (Order 82-38), § 296-17-512, filed
11/29/82, effective 1/1/83. Statutory Authority: RCW 51.04.030 and 51.16.035. 79-12-086 (Order 79-18), §
296-17-512, filed 11/30/79, effective 1/1/80; Order 74-40, §
296-17-512, filed 11/27/74, effective 1/1/75; Order 73-22, §
296-17-512, filed 11/9/73, effective 1/1/74.]