WAC 246-359-600
Alternate construction. (1) The department
will allow alternate construction to the requirements stated in
WAC 246-359-200 through 246-359-440 of this chapter when the
plans are designed and stamped by an engineer or architect
licensed to practice in the state of Washington.
(2) Any changes in the structural design must be stamped by
an engineer including:
(a) Fixed construction, which cannot be dismantled and
stored. Such fixed construction must comply with the structural
requirements of the state building code, for example, wind
forces, seismic forces, snow load, live load, and dead load.
(b) Nonfixed construction which can be dismantled and stored
for use when ice or snow exceed the snow loads stated in this
chapter. Such nonfixed construction must comply with the
structural requirements of the state building code, for example,
wind forces, seismic forces, live load, and dead load with the
exception of snow loads.
(3) To determine compliance with this section the department
may require a special inspector to conduct special inspections.
[Statutory Authority: RCW 70.114A.081. 99-03-065, §
246-359-600, filed 1/18/99, effective 2/18/99.]