TABLE 4 MAXIMUM RADIUS COVING OR POOL INTRUSION DIMENSIONS BETWEEN POOL FLOOR AND WALL* |
||||||||
| Pool Depth | 2'0" | 2'6" | 3'0" | 3'6" | 4'0" | 4'6" | 5'0" | >5'0" |
| Minimum Slide Wall | ||||||||
| Vertical Depth | 1'6" | 1'10" | 2'2" | 2'6" | 2'10" | 3'2" | 3'6" | >3'6" |
| Maximum Radius | ||||||||
| of Curvature | 6" | 8" | 10" | 12" | 1'2" | 1'4" | 1'6" | **Maxi-mum radius equals pool depth minus the vertical wall depth |
| Note: |
|
| Note: |
|
![]() |
Dimension |
Minimum |
Preferred or Maximum |
|
| A | Height of board above water | 20 in. | |
| B | Board overhang | 2 ft 6in. | 3 ft |
| C | Depth of water at plummet | 9 ft | 10 ft* |
| D | Distance from plummet to start of upslope | 16 ft | 18 ft* |
| E | Inclination of upslope of bottom | 1:3 | |
| F | Depth of water at breakpoint | 4 ft 6 in. | |
| G | Slope of bottom in shallow portion of pool | 1:12 | 1:15* |
| H | Length of shallow section of pool | 8 ft | 14 ft* |
| I | Distance to any overhead structure | 13 ft | 15 ft* |
| K | Board length | 12 ft | |
| L | Length of pool | 40 ft | 50 ft* |
| M | Dimension not less than C minus | 6 in. | |
| Note: |
|
| Note: |
|
![]() |
Dimensions |
SPRINGBOARD |
PLATFORM |
||||||||||||||
| FINA | are in Metres | 1 Metre | 3 Metres | 1 Metres | 3 Metres | 5 Metres | 7.5 Metres | 10 Metres | ||||||||
| DIMENSIONS FOR | LENGTH | 4.80 | 4.80 | 4.50 | 5.00 | 6.00 | 6.00 | 6.00 | ||||||||
| DIVING FACILITIES | WIDTH | 0.50 | 0.50 | 0.60 | 1.50 | 1.50 | 1.50 | 2.00 | ||||||||
| Revised to 1st Jan 1987 | HEIGHT | 1.00 | 3.00 | 0.60-1.00 | 2.60-3.00 | 5.00 | 7.50 | 10.00 | ||||||||
| HORIZ | VERT | HORIZ | VERT | HORIZ | VERT | HORIZ | VERT | HORIZ | VERT | HORIZ | VERT | HORIZ | VERT | |||
| A | From plummet BACK TO POOL WALL |
DESIGNATION | A-1 | A-3 | A-1P1 | A-3P1 | A-5 | A-7.5 | A.10 | |||||||
| MINIMUM | 1.80 | 1.80 | 0.75 | 1.25 | 1.25 | 1.50 | 1.50 | |||||||||
| A/A | From plummet BACK TO PLATFORM Plummet directly below |
DESIGNATION | AA5/1 | AA7.5/3/1 | AA10/5/3/1 | |||||||||||
| MINIMUM | 1.50 | 1.50 | 1.50 | |||||||||||||
| B | From plummet to POOL WALL AT SIDE |
DESIGNATION | B-1 | B-3 | B-1p1 | B-3p1 | B-5 | B-7.5 | B-10 | |||||||
| MINIMUM | 2.50 | 3.50 | 2.30 | 2.90 | 4.25 | 4.50 | 5.25 | |||||||||
| C | From plummet to ADJACENT PLUMMET |
DESIGNATION | C-1/1 | C-3/3/1 | C-1/1p1 | C-3/1P1/3p1 | C-5/3/1 | C-7.5/5/3/1 | C-10/7.5/5/3. | |||||||
| MINIMUM | 2.40 | 2.60 | 1.65 | 2.10 | 2.50 | 2.50 | 2.75 | |||||||||
| D | From plummet to POOL WALL AHEAD |
DESIGNATION | D-1 | D-3 | D-1p1 | D-3p1 | D-5 | D-7.5 | D-10 | |||||||
| MINIMUM | 9.00 | 10.25 | 8.00 | 9.50 | 10.25 | 11.00 | 13.50 | |||||||||
| E | On plummet, from BOARD TO CEILING |
DESIGNATION | E-1 | E-3 | E-1p1 | E-3p1 | E-5 | E-7.5 | E-10 | |||||||
| MINIMUM | 5.00 | 5.00 | 3.50 | 3.50 | 3.50 | 3.50 | 5.00 | |||||||||
| F | CLEAR OVERHEAD behind and each side of plummet |
DESIGNATION | F-1 | E-1 | F-3 | E-3 | F-1p1 | E-1p1 | F-3p1 | E-3p1 | F-5 | E-5 | F-7.5 | E-7.5 | F-10 | E-10 |
| MINIMUM | 2.50 | 5.00 | 2.50 | 5.00 | 2.75 | 3.50 | 2.75 | 3.50 | 2.75 | 3.50 | 2.75 | 3.50 | 2.75 | 5.00 | ||
| G | CLEAR OVERHEAD ahead of plummet |
DESIGNATION | C-1 | E-1 | C-3 | E-3 | G-1p1 | E-1p1 | G-3p1 | E-3p1 | G-5 | E-5 | G-7.5 | E-7.5 | G-10 | E-10 |
| MINIMUM | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | 3.50 | 5.00 | 3.50 | 5.00 | 3.50 | 5.00 | 3.50 | 6.00 | 5.00 | ||
| H | DEPTH OF WATER at plummet |
DESIGNATION | H-1 | H-3 | H-1p1 | H-3p1 | H-5 | H-7.5 | H-10 | |||||||
| MINIMUM | 3.50 | 3.80 | 3.30 | 3.60 | 3.80 | 4.50 | 5.00 | |||||||||
| J | DISTANCE AND DEPTH | DESIGNATION | J-1 | K-1 | J-3 | K-3 | J-1p1 | K-1p1 | J-3p1 | K-3p1 | J-5 | K-5 | J-7.5 | K-7.5 | J-10 | K-10 |
| K | ahead of plummet | MINIMUM | 5.00 | 3.40 | 6.00 | 3.70 | 5.00 | 3.20 | 6.00 | 3.50 | 6.00 | 3.70 | 8.00 | 4.40 | 11.00 | 4.75 |
| L | DISTANCE AND DEPTH | DESIGNATION | L-1 | M-1 | L-3 | M-3 | L-1p1 | M-1p1 | L-3p1 | M-3p1 | L-5 | M-5 | L-7.5 | M-7.5 | L-10 | M-10 |
| M | each side of plummet | MINIMUM | 1.50 | 3.40 | 2.00 | 3.70 | 1.40 | 3.20 | 1.80 | 3.50 | 4.25 | 3.70 | 4.50 | 4.40 | 5.25 | 4.75 |
| N | MAXIMUM SLOPE TO REDUCE DIMENSIONS beyond full requirements |
POOL DEPTH CEILING HT |
30 degrees 30 degrees |
NOTE Dimensions C (plummet to adjacent plummet) apply for Platform with widths as detailed. For wider Platforms increase C by half the additional width(s) |
||||||||||||
![]() |
| Number of Main Drains Per Recirculation System |
||||
| 2 | 3 | 4 | 5 | |
| Main drain rated flow capacity must be at least equal to the percent of maximum pump flow indicated, depending on the number of main drains. | 100% | 50% | 33.3% | 25% |
TABLE 6 FILTER TYPES AND ACCEPTABLE RATES |
|||
| Range of Acceptable Filter Rate Expressed in gpm/sq. ft. |
|||
| Type of Filter | Minimum | Maximum* | |
| Sand | |||
| Rapid & pressure | -- | 3 | |
| Pressure high rate | 10 | 18 | |
| Vacuum high rate | 10 | 18 | |
| DE | Continuous feed |
Manual feed |
|
| Vacuum | 0.8 | 1.0 | 2.0 |
| Pressure | 1.0 | 1.35 | 2.0 |
| Cartridge** | |||
| Applied in | |||
| temperature | |||
| ranges: | |||
| <95°F. | -- | 0.375 | |
| >95°F. | -- | 0.188 |
|
| Note: |
|
TABLE 7 MINIMUM PLUMBING FIXTURE REQUIREMENTS BASED ON MAXIMUM PEAK PERIOD OCCUPANCY |
||||
| Number of Fixtures
Required Per Occupancy Load |
||||
| Type of Fixture | Occupancy/Sex | Male | Female | |
| 1. | Toilets | First 600 | 1/200 | 1/100 |
| Portion | ||||
| exceeding 600 | 1/450 | 1/300 | ||
| 2. | Urinals | First 600 | 1/200 | - |
| Portion | ||||
| exceeding 600 | 1/450 | - | ||
| 3. | Showers | First 300 | 1/100 | 1/100 |
| Portion | ||||
| exceeding 300 | 1/200 | 1/200 | ||
| 4. | Sinks | First 400 | 1/200 | 1/200 |
| Next 350 | 1/350 | 1/350 | ||
| Portion | ||||
| exceeding 750 | 1/500 | 1/500 | ||
| 5. | Hose bibs | 1 accessible to change rooms | ||
| 6. | Janitor sink | 1 within the RWCF |
||