WAC 246-244-115
Energy compensation sources and tritium
neutron generator target sources. (1) The licensee may use an
energy compensation source (ECS) which is contained within a
logging tool, or other tool components, only if the ECS
contains quantities of licensed material not exceeding 3.7 MBq
(100 microcuries).
(a) For well-logging applications with a surface casing
for protecting fresh water aquifers, use of the ECS is only
subject to the requirements of WAC 246-244-080, 246-244-090
and 246-244-100.
(b) For well-logging applications without a surface
casing for protecting fresh water aquifers, use of the ECS is
only subject to the requirements of WAC 246-244-030,
246-244-080, 246-244-090, 246-244-100 and 246-244-240.
(2) Use of a tritium neutron generator target source,
containing quantities not exceeding 1,110 MBq (30 curies) and
in a well with a surface casing to protect fresh water
aquifers, is subject to the requirements of this chapter
except WAC 246-244-030, 246-244-110, and 246-244-240.
(3) Use of a tritium neutron generator target source,
containing quantities exceeding 1,110 MBq (30 curies) or in a
well without a surface casing to protect fresh water aquifers,
is subject to the requirements of this chapter except WAC 246-244-110.
[Statutory Authority: RCW 70.98.050. 03-12-062, §
246-244-115, filed 6/2/03, effective 7/3/03.]