WAC 246-229-0090
What are the minimum requirements for
particle accelerator use? The minimum requirements for the
registrant to use a particle accelerator are to:
(1) Register the accelerator with the department;
(2) Submit plan review/shielding design to the department
and receive written approval;
(3) Train operators and users;
(4) Complete a qualified expert's radiation protection
survey of the room/area initially and after any changes in
shielding, equipment, or occupancy of adjacent areas;
(5) Provide appropriate portable radiation monitoring
equipment that is operable and tested daily, and calibrated every
six months, or after any service/repair;
(6) Develop operating and emergency procedures and keep a
copy of the current procedures at the accelerator control panel;
and
(7) If applicable, provide the means and guidance to
determine airborne particulate radioactivity present in areas of
airborne hazards, and/or particulate radiation contamination
(smear surveys) in target and other pertinent areas.
[Statutory Authority: RCW 70.98.050 and [70.98.]080. 02-14-050,
§ 246-229-0090, filed 6/27/02, effective 7/28/02.]