WAC 246-221-060
Dose limits for individual members of
the public. (1) Each licensee or registrant shall conduct
operations so that:
(a) The total effective dose equivalent to individual
members of the public from the licensed or registered
operation does not exceed 1 mSv (0.1 rem) in a year, exclusive
of the dose contributions from background radiation, from any
medical administration the individual has received, from
exposure to individuals administered radioactive material and
released under chapter 246-240 WAC, from voluntary participation in medical research
programs, and from the licensee's or registrant's disposal of
radioactive material into sanitary sewerage in accordance with
WAC 246-221-190; and
(b) The dose in any unrestricted area from external
sources, exclusive of the dose contributions from patients
administered radioactive material and released under chapter 246-240 WAC, does not exceed
0.02 mSv (0.002 rem) in any one hour.
(2) If the licensee or registrant permits members of the
public to have access to restricted areas, they shall be
escorted and the limits for members of the public continue to
apply to those individuals.
(3) Notwithstanding subsection (1) of this section, a
licensee or registrant may continue to operate a facility
constructed and put into operation prior to January 1, 1994,
where the annual dose limit for an individual member of the
public is more than 1 mSv (0.1 rem) and less than 5 mSv (0.5
rem) total effective dose equivalent, if:
(a) The facility's approved operating conditions for each
radiation source remain the same. Any increase in the
following operating conditions shall require reevaluation by
the department and/or modification of the facility shielding
applicable to the source of radiation to meet the 1 mSv (0.1
rem) total effective dose equivalent limit for individual
members of the public: size of the radiation source,
workload, or occupancy factors associated with the source of
radiation; and
(b) Any change in the permanent shielding of the facility
due to remodeling, repair or replacement requires
the facility to meet the 1 mSv (0.1 rem) total effective dose
equivalent limit for individual members of the public for
areas affected by that portion of the shielding.
(4) Each licensee or registrant shall maintain records
sufficient to demonstrate compliance with the dose limit for
individual members of the public.
[Statutory Authority: RCW 70.98.050. 06-05-019, §
246-221-060, filed 2/6/06, effective 3/9/06; 98-13-037, §
246-221-060, filed 6/8/98, effective 7/9/98; 94-01-073, §
246-221-060, filed 12/9/93, effective 1/9/94. Statutory
Authority: RCW 70.98.050 and 70.98.080. 91-15-112 (Order
184), § 246-221-060, filed 7/24/91, effective 8/24/91. Statutory Authority: RCW 43.70.040. 91-02-049 (Order 121),
recodified as § 246-221-060, filed 12/27/90, effective
1/31/91. Statutory Authority: RCW 70.98.080. 87-01-031
(Order 2450), § 402-24-040, filed 12/11/86. Statutory
Authority: RCW 70.98.050. 81-01-011 (Order 1570), §
402-24-040, filed 12/8/80; Order 1095, § 402-24-040, filed
2/6/76; Order 1, § 402-24-040, filed 1/8/69; Rules (part),
filed 10/26/66.]