WAC 173-306-480
Treatment (including solidification and
stabilization) standards. (1) Applicability. The standards of
this section apply to treatment, as defined in WAC 173-306-100,
of any special incinerator ash subject to this chapter. These
standards do not apply to the manual or mechanical removal of
ferrous metal from ash residues.
(2) Requirements. All owners and operators shall design,
construct, operate, maintain, and close treatment facilities so
as to:
(a) Meet the general facility standards of WAC 173-306-405;
(b) Only treat special incinerator ash in tanks, reaction
vessels, furnaces (such as glass furnaces), containers, or
totally enclosed treatment facilities (such as pipelines). No
treatment process may be designed to occur in ash piles, surface
impoundments, or land treatment facilities;
(i) The department shall review and approve tank and
reaction vessel design. All tanks and reaction vessels will be
closed or otherwise designed to avoid emissions of dusts or
vapors to the atmosphere. Tanks and reaction vessels must be of
sufficient thickness and corrosion resistance to prevent rupture;
(ii) Totally enclosed treatment facilities must be in good
condition and of a design and construction to avoid rupture under
maximum operating conditions and must be capable of being
inspected periodically; and
(iii) Furnaces must be in good condition structurally,
designed and operated to accept only special incinerator ash and
capable of being inspected periodically. The department may
review and approve furnace design.
(c) Meet the performance standards of WAC 173-306-440(2). The department shall specify the type and frequency of all
sampling and monitoring necessary to assure compliance.
(d) Assure that treatment of special incinerator ash occurs
under conditions spelled out in prototype, pilot plant or full
scale operation. The design must be approved by the department
and the department shall specify operating conditions.
(e) Control fugitive dust emissions in the handling of
special incinerator ash by:
(i) Collecting and handling in enclosed buildings or the
equivalent (e.g., covered conveyors and transfer points); and
(ii) Adding moisture, dust suppressants, or other methods as
necessary.
(f) Comply with chapter 296-62 WAC, the general occupational
health standards.
(g) Assure that treated special incinerator ash is disposed
of according to this chapter or chapter 173-304 WAC, the minimum
functional standards for solid waste, if the residues are
designated as solid waste.
(h) Close the treatment facility according to the
requirements of WAC 173-306-410.
[Statutory Authority: Chapter 70.138 RCW. 00-19-018 (Order
00-17), § 173-306-480, filed 9/8/00, effective 10/9/00;
90-10-047, § 173-306-480, filed 4/30/90, effective 5/31/90.]