WAC 173-303-083
Deletion of certain dangerous waste
codes following equipment cleaning and replacement. (1)
Wastes from wood preserving processes at plants that do not
resume or initiate use of chlorophenolic preservatives will
not meet the listing definition of F032 once the generator has
met all of the requirements of subsections (2) and (3) of this
section. These wastes may, however, continue to meet another
dangerous waste listing description or may exhibit one or more
of the dangerous waste characteristics.
(2) Generators must either clean or replace all process
equipment that may have come into contact with chlorophenolic
formulations or constituents thereof, including, but not
limited to, treatment cylinders, sumps, tanks, piping systems,
drip pads, fork lifts, and trams, in a manner that minimizes
or eliminates the escape of dangerous waste or constituents,
leachate, contaminated drippage, or dangerous waste
decomposition products to the groundwater, surface water, or
atmosphere.
(a) Generators will do one of the following:
(i) Prepare and follow an equipment cleaning plan and
clean equipment in accordance with this section;
(ii) Prepare and follow an equipment replacement plan and
replace equipment in accordance with this section; or
(iii) Document cleaning and replacement in accordance
with this section, carried out after termination of use of
chlorophenolic preservatives.
(b) Cleaning requirements.
(i) Prepare and sign a written equipment cleaning plan
that describes:
(A) The equipment to be cleaned;
(B) How the equipment will be cleaned;
(C) The solvent to be used in cleaning;
(D) How solvent rinses will be tested; and
(E) How cleaning residues will be disposed.
(ii) Equipment must be cleaned as follows:
(A) Remove all visible residues from process equipment;
(B) Rinse process equipment with an appropriate solvent
until dioxins and dibenzofurans are not detected in the final
solvent rinse.
(iii) Analytical requirements.
(A) Rinses must be tested in accordance with SW-846,
Method 8290 as incorporated by reference at WAC 173-303-110
(3)(a).
(B) "Not detected" means at or below the lower method
calibration limit (MCL) in accordance with SW-846, Method
8290, Table 1 as incorporated by reference at WAC 173-303-110
(3)(a).
(iv) The generator must manage all residues from the
cleaning process as F032 waste.
(c) Replacement requirements.
(i) Prepare and sign a written equipment replacement plan
that describes:
(A) The equipment to be replaced;
(B) How the equipment will be replaced; and
(C) How the equipment will be disposed.
(ii) The generator must manage the discarded equipment as
F032 waste.
(d) Documentation requirements. Document that previous
equipment cleaning and/or replacement was performed in
accordance with this section and occurred after cessation of
use of chlorophenolic preservatives.
(3) The generator must maintain the following records
documenting the cleaning and replacement as part of the
facility's operating record:
(a) The name and address of the facility;
(b) Formulations previously used and the date on which
their use ceased in each process at the plant;
(c) Formulations currently used in each process at the
plant;
(d) The equipment cleaning or replacement plan;
(e) The name and address of any persons who conducted the
cleaning and replacement;
(f) The dates on which cleaning and replacement were
accomplished;
(g) The dates of sampling and testing;
(h) A description of the sample handling and preparation
techniques, including techniques used for extraction,
containerization, preservation, and chain-of-custody of the
samples;
(i) A description of the tests performed, the date the
tests were performed, and the results of the tests;
(j) The name and model numbers of the instrument(s) used
in performing the tests;
(k) QA/QC documentation; and
(l) The following statement signed by the generator or
his authorized representative: I certify under penalty of law
that all process equipment required to be cleaned or replaced
under WAC 173-303-083 was cleaned or replaced as represented
in the equipment cleaning and replacement plan and
accompanying documentation. I am aware that there are
significant penalties for providing false information,
including the possibility of fine or imprisonment.
[Statutory Authority: Chapters 70.105 and 70.105D RCW. 09-14-105 (Order 07-12), § 173-303-083, filed 6/30/09,
effective 7/31/09; 95-22-008 (Order 94-30), § 173-303-083,
filed 10/19/95, effective 11/19/95; 94-01-060 (Order 92-33), §
173-303-083, filed 12/8/93, effective 1/8/94. Statutory
Authority: Chapter 70.105 RCW and RCW 70.95.260. 82-05-023
(Order DE 81-33), § 173-303-083, filed 2/10/82.]