WAC 173-160-458
What sealing materials are allowed for
sealing vibrating wire piezometers? (1) Vibrating wire
piezometers shall be sealed using materials as allowed in WAC 173-160-450; or sealing materials as designed and recommended
by the manufacturer provided that the material, when placed,
provides a permeability of 1 x 10-7 cm/sec or less. The
licensed driller or engineer shall provide documentation from
the manufacturer demonstrating that the sealing material meets
the permeability requirements of this section.
(2) The use of bentonite products intended for use as
drilling fluids, low solids content bentonite mixtures, fly
ash, and hydrated lime are prohibited as additives or
sealants.
[Statutory Authority: Chapter 18.104 RCW. 09-01-125 (Order
08-10), § 173-160-458, filed 12/19/08, effective 1/19/09.]