WAC 51-50-480807
Section 807 -- Structural.
807.4.1 Evaluation and analysis. An engineering evaluation
and analysis that establishes the structural adequacy of the
altered structure shall be prepared by a registered design
professional and submitted to the code official. For
structures assigned to Seismic Design Category D, the
registered design professional shall submit to the code
official a seismic evaluation report of the existing building
based on one of the procedures specified in Section 101.5.4.2.
This seismic evaluation report shall not be required for
buildings in compliance with the benchmark building provisions
of ASCE 31, Section 3.2.
807.4.2 Substantial structural alteration. Any building or
structure undergoing substantial improvement shall have an
evaluation and analysis to demonstrate that the altered
building or structure complies with the International Building
Code for wind loading and with reduced International Building
Code level seismic forces as specified in Section 101.5.4.2
for seismic loading. For seismic considerations, the analysis
shall be based on one of the procedures specified in Section101.5.4
.
807.4.3 Limited structural alteration. Where any building or
structure undergoes less than substantial improvement, the
evaluation and analysis shall demonstrate that the altered
building or structure complies with the loads applicable at
the time the building was constructed.
[Statutory Authority: RCW 19.27.031 and 19.27.074. 10-03-097, § 51-50-480807, filed 1/20/10, effective 7/1/10. Statutory Authority: RCW 19.27.074, 19.27.020, and chapters 70.92, 19.27, and 34.05 RCW. 07-01-091, § 51-50-480807, filed