Reserved.
Section 3002 -- Hoistway enclosures.
3002.4 Elevator car to accommodate ambulance stretcher. In
buildings four stories in height or more, and in buildings
which are required to have an elevator and contain Group R-1,
R-2 or I Occupancies on a level other than the exit discharge
level, at least one elevator shall be provided for fire
department emergency access to all floors. Such elevator car
shall be of such a size and arrangement to accommodate a
24-inch by 84-inch (610 mm by 2134 mm) ambulance stretcher
with not less than 5-inch (127 mm) radius corners, in the
horizontal, open position and shall be identified by the
international symbol for emergency medical services (star of
life). The symbol shall not be less than 3 inches (76 mm)
high and shall be placed inside on both sides of the hoistway
door frame.