WAC 16-202-1019
What alternative methods may be used for
product injection? Alternative technology used for product
injection must fulfill the provisions of this chapter. With a
surface supplied water source, the injection point must occur
downstream from the point of diversion. With a pressurized water
source, the injection point must be located such that product
backflow cannot occur.
(1) Injection with barometric loops.
(a) Barometric loops can only be used on systems pumping
from a surface water source.
(b) The barometric pipe loop must be located in the water
line immediately downstream of the irrigation water pump.
(c) A barometric pipe loop must be designed with sufficient
elevation differential to compensate for backflow.
(d) The bottom of the barometric loop apex must be at least
thirty inches above the highest water-emitting device or of any
portion of the irrigation application system.
(e) The barometric loop must contain a vacuum relief device
at the loop apex that allows air into the pipeline immediately
upon loss of pressure. The orifice size must comply with current
American Society of Agricultural Engineers (ASAE) standards.
(f) The injection point on a barometric loop must be located
downstream of and at least thirty inches below the bottom of the
barometric pipe loop apex.
(2) Solenoid and check valve.
(a) The chemical injection line must contain either a
normally closed solenoid-operated valve connected to the system
interlock or a normally closed hydraulically operated valve that
opens only when the main water line is adequately pressurized. A
normally closed, solenoid-operated valve must be placed on the
intake side of the injection pump, immediately adjacent to the
application tank.
(b) The chemical injection line between the application tank
and the metering device must contain an automatic, quick-closing
check valve to prevent the flow of liquid back toward the
application tank. The check valve must be placed immediately
adjacent to the venturi chemical inlet.
[Statutory Authority: Chapters 15.54, 15.58, 17.21, and 34.05 RCW. 01-23-018, § 16-202-1019, filed 11/9/01, effective