WAC 16-201-030
Secondary containment of liquid bulk
fertilizers -- Lining. If a liner is required to meet the
standards set forth in WAC 16-201-028, then it must be
constructed as follows:
(1) Synthetic liners:
(a) Synthetic liners shall be chemically compatible with
the materials being stored within the permanent storage
facility and have a minimum thickness of thirty mils +/-1 mil.
A written confirmation of compatibility and a written
estimate of the life of the liner from the manufacturer shall
be kept on file at the permanent storage facility or the
nearest local office from which the permanent storage facility
is administered.
(b) Synthetic liners shall be installed under the
supervision of a qualified representative of the manufacturer,
a contractor certified by the manufacturer, or a certified
engineer. All field constructed seams shall be tested, and
repaired if necessary, in accordance with the manufacturer's
recommendations.
(2) Permanent storage facilities with storage containers
of one hundred thousand gallons or greater may use clay soil
liners: Provided, That:
(a) The surface soil shall be sealed, including the berm
of an earthen dike, with a sealing agent such as sodium
bentonite, attapulgite or a similar clay material[;]
(b) The liner shall be constructed in accordance with
reliable civil engineering practices, to achieve a coefficient
of permeability not to exceed 1x10-6 cm/sec and shall be
maintained at 1x10-5 cm/sec with a thickness of not less than
six inches[.][;]
(c) The floor and internal walls of the containment area
shall have a protective barrier to prevent desiccation,
evaporation, freeze, thaw, or other physical damage.
[Statutory Authority: RCW 15.54.800. 00-23-075, §
16-201-030, filed 11/17/00, effective 12/18/00. Statutory
Authority: RCW 15.54.800 and 15.58.040. 93-22-093 (Order
5018), § 16-201-030, filed 11/2/93, effective 3/1/94.]
NOTES:
Reviser's note: RCW 34.05.395 requires the use of underlining and deletion marks to indicate amendments to existing rules, and deems ineffectual changes not filed by the agency in this manner. The bracketed material in the above section does not appear to conform to the statutory requirement.