WAC 16-125-200
Recording thermometers -- Installation. (1)
All new farm bulk tank installations must include a recording
thermometer and an automatic interval timer. Installation of a
used milk tank will be regarded as a new installation.
(2) The installation and operation of recording thermometers
and interval timers shall be the responsibility of the holder of
the Grade A producer permit.
(3) Recording devices must not be attached to a farm tank.
Recording devices may be suspended on metal brackets from the
ceiling, firmly attached to the inside wall of the milk room, or
at any other location acceptable to the department. The
recording device must be mounted no more than six feet from the
floor or be otherwise accessible from the floor without the
necessity of climbing.
(4) The sensor bulb or device must be located so as to
record the temperature of the milk in the tank before the milk
reaches twenty percent of the tank volume. A capillary system
containing toxic gas or liquids must not be used in a bare bulb
sensor device.
(5) The recorder and chart must be capable at a minimum of
recording from thirty-two degrees to one hundred eighty degrees
F, or above, and must be accurate within plus or minus two
degrees F.
(6) The case of the recording device must be moisture-proof
under operating conditions in the milk house or milk room.
(7) The recording chart must make at a minimum one
revolution every seven days. A strip chart must not be used.
(8) The recording clock must be electrically operated. The
recorder pen must be set to the actual time.
(9) If at any time, the recording device becomes inoperable
or out of tolerance, the inspection service and the pooling agent
or hauler must be notified immediately by the producer. Repair
or replacement of the device must be made as soon as possible.
(10) The producer must maintain an adequate supply of
recording charts. The charts must fit the specific instrument
installed.
(11) To prevent stratification of the milk in the tank the
interval timer must be set so the milk will be agitated for at
least five minutes every hour.
[Statutory Authority: RCW 15.36.020. 99-18-032, § 16-125-200,
filed 8/25/99, effective 9/25/99. Statutory Authority: Chapter 15.36 RCW. 86-17-014 (Order 1902), § 16-125-200, filed 8/8/86.]