WAC 16-125-030
Installation. Before any person installs a
new tank or relocates a used tank, he or she must file drawings
and detailed information about where and how the milk storage
tank is to be installed with the director. There must be a
minimum of two feet clearance between the sides of the tank and
the walls of the milkhouse or other permanent equipment and a
minimum of three feet on the working side of the tank and at the
outlet valve. Adequate additional space necessary for normal
milkhouse operations must be provided. There must be at least 30
inches clearance between the top of the pouring tank lip and the
ceiling. Adequate space must be provided above the tank to
accommodate the measuring rod.
Provisions of the National Bureau of Standards' Handbook 44
Code on Farm Milk Tanks as adopted under chapter 19.94 RCW
applicable to installation and use shall be applicable.