| DETERMINING WIND FACTOR (See the board manual section 12 for detailed examples.) |
|||||
| Favorable | Calm or Unfavorable | ||||
| NOZZLE TYPE | APPLICATION HEIGHT | BUFFER ON
WATER |
OFFSET FROM INNER ZONE | BUFFER ON WATER | OFFSET FROM INNER ZONE |
| Regular Nozzle* |
Low (≤ 16 ft.) | Width of the inner zone | As needed for safety | 100 ft., or the inner zone, whichever is greater | 50 ft. |
| Medium (17-50 ft.) |
Width of the inner zone | As needed for safety | 250 ft. | N/A | |
| High (51-65 ft.) |
Width of the inner zone | As needed for safety | 325 ft. | N/A | |
| Raindrop Nozzle (or other nozzles that result in the same size spray droplets)** | Low (≤ 16 ft.) | Width of the inner zone | As needed for safety | Width of inner zone | 20 ft. |
| Medium (17-50 ft.) |
Width of the inner zone | As needed for safety | Width of inner zone | 20 ft. | |
| High (51-65 ft.) |
Width of the inner zone | As needed for safety | 125 ft. or the inner zone, whichever is greater | 20 ft. | |
| * | Coarse spray droplets = approximately 9% of spray-droplet volume ≤ 150 u |
| ** | Ultra coarse spray droplets = approximately 1% of spray-droplet volume ≤ 150 u |
| DETERMINING WIND FACTOR (See the board manual section 12 for detailed examples.) |
|||||
| Favorable | Calm or Unfavorable | ||||
| NOZZLE TYPE | APPLICATION HEIGHT | BUFFER ON
WETLAND |
OFFSET FROM WMZ | BUFFER ON WETLAND | OFFSET FROM WMZ |
| Regular Nozzle* |
Low (≤ 16 ft.) |
Width of the WMZ | As needed for safety | 150 ft. | N/A |
| Medium (17-50 ft.) |
Width of the WMZ | As needed for safety | 250 ft. | N/A | |
| High (51-65 ft.) |
Width of the WMZ | As needed for safety | 325 ft. | N/A | |
| Raindrop Nozzle (or other nozzles that result in the same size spray droplets)** | Low (≤ 16 ft.) | Width of the WMZ | As needed for safety | Width of WMZ | 20 ft. |
| Medium (17-50 ft.) |
Width of the WMZ | As needed for safety | Width of WMZ | 20 ft. | |
| High (51-65 ft.) |
Width of the WMZ | As needed for safety | 125 ft. or the width of the WMZ, whichever is greater | 20 ft. | |
| * | Coarse spray droplets = approximately 9% of spray-droplet volume ≤ 150 u |
| ** | Ultra coarse spray droplets = approximately 1% of spray-droplet volume ≤ 150 u |
| DETERMINING WIND FACTOR (See the board manual section 12 for detailed examples.) |
||
| Favorable | Calm or Unfavorable | |
| Nozzle Type | Buffer | Buffer |
| Regular Nozzle | 50 ft. | 100 ft. |
| Raindrop Nozzle (or other nozzles that result in the same size spray droplets)* | 50 ft. | 70 ft. |
| * | Coarse spray droplets = approximately 9% of spray-droplet volume ≤ 150 u |