WAC 51-56-0300
Chapter 3 -- General regulations.
301.1.3 Standards. Standards listed or referred to in this
chapter or other chapters cover materials which will conform
to the requirements of this code, when used in accordance with
the limitations imposed in this or other chapters thereof and
their listing. Where a standard covers materials of various
grades, weights, quality, or configurations, there may be only
a portion of the listed standard which is applicable. Design
and materials for special conditions or materials not provided
for herein are allowed to be used by special permission of the
authority having jurisdiction after the authority having
jurisdiction has been satisfied as to their adequacy in
accordance with Section 301.2.
311.4 Except as hereinafter provided in Sections 908.0, 909.0,
910.0, and Appendix L, Section L 6.0, 7.0 and 8.0, no vent
pipe shall be used as a soil or waste pipe, nor shall any soil
or waste pipe be used as a vent.
313.6 No water, soil, or waste pipe shall be installed or
permitted outside of a building or in an exterior wall unless,
where necessary, adequate provision is made to protect such
pipe from freezing. All hot and cold water pipes installed
outside the conditioned space shall be insulated to a minimum
R-3.
313.7 All pipe penetrating floor/ceiling assemblies and
fire-resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
[Statutory Authority: RCW 19.27.190, 19.27.020 and chapters 19.27 and 34.05 RCW. 07-01-094, § 51-56-0300, filed 12/19/06,
effective 7/1/07. Statutory Authority: RCW 19.27.031 and 19.27.074. 04-01-110, § 51-56-0300, filed 12/17/03, effective
7/1/04; 02-01-114, § 51-56-0300, filed 12/18/01, effective
7/1/02.]