WAC 51-50-481105
Section 1105 -- Change of occupancy.
1105.10 One-hour fire-resistant assemblies. Where one-hour
fire-resistance-rated construction is required by these
provisions, it need not be provided, regardless of
construction or occupancy, where the existing wall and ceiling
finish is wood lath or metal lath and plaster.
1105.14 Natural light. When it is determined by the
professional responsible for the historical documentation of
the project that compliance with the natural light
requirements of Section 911.1 will lead to loss of historic
character or historic materials in the building, the existing
level of natural lighting shall be considered acceptable.
[Statutory Authority: RCW 19.27.074, 19.27.020, and chapters 70.92, 19.27, and 34.05 RCW. 07-01-091, § 51-50-481105, filed
12/19/06, effective 7/1/07.]