IBC Table 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE
LOADS AND MINIMUM CONCENTRATED LIVE LOADS
| OCCUPANCY OR
USE |
UNIFORM
(psf) |
CONCENTRATED
(psf) |
| 4. Assembly areas
and theaters |
|
|
| Fixed seats (fastened
to floor) |
60 |
|
| Follow spot,
projections, and
control rooms |
50 |
|
| Lobbies |
100 |
-------- |
| Movable seats |
100 |
|
| Stages and platforms |
125 |
|
| Other assembly areas |
100 |
|
| 5. (Reserved) |
|
-------- |
| 9. Decksh and
Balconies |
Same as
occupancy
served |
-------- |
| 28. Residential |
|
|
| One- and two-family
dwellings |
|
|
| |
Uninhabitable
attics without
storagei |
10 |
|
| |
Uninhabitable
attics with limited
storagei, j, k |
20 |
|
| |
Habitable attics and
sleeping areas |
30 |
-------- |
| |
All other areas |
40 |
|
| Hotels and
multifamily dwellings |
|
|
| |
Private rooms and
corridors serving
them |
40 |
|
| |
Public rooms and
corridors serving
them |
100 |
|