WAC 51-11-0527   Equation 3 -- Group R Occupancy.  

EQUATION 3 -- GROUP R OCCUPANCY

PROPOSED UA

UA = UWAW+ UBGWABGW+ UVGAVG+ UOGAOG+ UFAF+ URCARC+ UCCACC+ UDAD+ FSPS
Where:
UA = the combined thermal transmittance of the gross exterior wall, floor and roof/ceiling assembly area.
UW = the thermal transmittance of the opaque wall area.
AW = opaque wall area.
UBGW = the thermal transmittance value of the below grade opaque wall area.
ABGW = opaque below grade wall area.
UVG = the thermal transmittance value of the vertical glazing area.
AVG = vertical glazing area, including windows in exterior doors.
UOG = the thermal transmittance value of the overhead glazing area.
AOG = overhead glazing area.
UF = the thermal transmittance of the floor area.
AF = floor area over unconditioned space.
URC = the thermal transmittance of the roof/ceiling area.
ARC = roof/ceiling area.
UCC = the thermal transmittance of the cathedral ceiling area.
ACC = cathedral ceiling area.
UD = the thermal transmittance value of the opaque door area.
AD = opaque door area.
FS = concrete slab component F-factor.
PS = lineal ft. of concrete slab perimeter.
NOTE : Where more than one type of wall, window, roof/ceiling, door and skylight is used, the U and A terms for those items shall be expanded into sub-elements as:
  UW1AW1+ UW2AW2+ UW3AW3+ . . . etc.




[Statutory Authority: RCW 19.27A.025 and 19.27A.045. 98-03-003, § 51-11-0527, filed 1/8/98, effective 7/1/98. Statutory Authority: Chapters 19.27, 19.27A and 34.05 RCW. 94-05-059, § 51-11-0527, filed 2/10/94, effective 4/1/94. Statutory Authority: Chapter 19.27A RCW. 92-01-140, § 51-11-0527, filed 12/19/91, effective 7/1/92.]